Milwaukee has a wide assortment of pH, ORP, Conductivity and other specialty sensors to meet all your specific requirements. Finding the right electrode for a specific application is a very important task and in order to solve this selection problem it is important to consider the following: electrode body, reference construction and junction. Below you will find a list of Milwaukee electrodes and probes with corresponding instruments they are supplied with. Special electrodes for specific applications can also be manufactured upon request.

MA811/2

MA811/2
Conductivity/TDS probe with 2 meter cable

MA814DB/1

MA814DB/1
4-ring Conductivity/TDS/NaCl/Temperature probe
with DIN connector and 1 meter cable
(for Mi170 & Mi180)

MA814DB/1

MA814D/1
4-ring Conductivity/TDS/NaCl/Temperature probe with DIN connector and 1 meter cable
(for Mi306)

MA830R

MA830R
Stainless steel Temperature probe (for SM102)

MA831R

MA831R
Stainless steel Temperature probe

MA840/3

MA840/3
Polarographic D.O. probe with 3 meter cable
(for SMS600 & Mi605)

MA851D/1

MA851D/1
pH/Conductivity/TDS/Temperature amplified probe with DIN connector and 1 meter cable (for Mi805 & Mi806)

MA911B/1 - MA911B/3

MA911B/2
Double junction, gel filled pH electrode with BNC connector, with 2 meter cable

MA916B/1 - MA916B/3

MA916B/1 - MA916B/3   
Combined glass pH electrode, refillable, BNC connector with 1 or 3 meter cable

MA917B/1

MA917B/1  
Combined glass pH electrode, double junction, refillable, BNC connector, 1 meter cable

MA918B/1

MA918B/1  
Combined glass pH electrode with 3 Diaphrams, double junction, refillable, BNC connector, 1 meter cable

MA919B/1
MA919B/1   
Glass pH electrode (for Mi456)
MA920B/1

MA920B/1   
Combined pH electrode with free diffusion layer junction, Viscolene cell with BNC connector and 1 meter cable

MA924B/1
MA924B/1  
Glass ORP electrode, with 1 m cable (for Mi455)
MA991B/1

MA991B/1  
Combined glass pH electrode with BNC connector and 1 meter cable

Mi56P
pH/Temp
probe (for pH55 and pH56)
Mi57P
ORP/Temp
probe (for ORP57)
Mi58P
pH/ORP/Temp
probe(for pH58)
Mi59P
Conductivity/TDS/Temp
probe (for EC59 and EC60)
SE220 SE220
Double junction, gel filled pH electrode with BNC connector, with 1 or 3 meter cable
SE300 SE300
Double junction, gel filled ORP electrode with platinum sensor, with BNC connector and 1 or 2 meter cable
SE510 SE510
Conductivity/TDS probe with DIN connector and 1 meter cable
(for MW401)
SE520 SE520
Conductivity/TDS probe with 1 meter cable
(for MW302 & MW402)
SE600
Combionation probe for pH/EC/TDS with 1 meter cable
(for MW801 and MW802)